| GENERAL CHARACTERISTICS | |||
|---|---|---|---|
| CASE | Self-extinguishing thermoplastic material | ||
| PROTECTION CLASS | IP67 - IEC/EN 60529 | ||
| RATIO | 1:12, 1:25, 1:33, 1:50, 1:75, 1:100, 1:150, 1:200, 1:400 | ||
| DIRECT RATIO | 1:25, 1:50 | ||
| SHAFT TYPE | Stainless steel mounted on self-lubricating bush protected by sealing rings on both sides Double overhang shaft version available on request | ||
| FIXING TYPE | Base fixing Front fixing (flanged) | ||
| MICRO SWITCHES | Nr 4 max - micrometric adjustment of roller lever (long life) | ||
| CAM BLOCK | Self-lubricating with transparent support for easier cam viewing | ||
| CABLE ENTRY | M16 (max 2) | ||
| AMBIENTAL TEMPERATURE | Operating: -25°C ... +70°C Storage: -30°C ... +70°C | ||
| ELECTRICAL CHARACTERISTICS | |||
| MICRO SWITCHES CONNECTIONS | MFI.3 - 6.3 x 0.8 faston terminal MFI.3STP - Screws M3 for wire 1.5 mm2 with plate protection | ||
| STANDARD CONFORMITY | IEC / EN 61058-1, UL 1054, EN 60204-1, EN 60947-1, EN 60947-5-1 | ||
| MARKING | CE, CRUus, CCC, EAC | ||
| RATED INSULATION VOLTAGE Ui | 250V | ||
| RATHED THERMAL CURRENT - Ith | 8A | ||
| RATHED OPERATING CURRENT | Resistive Load | 8A-250 V AC | |
| Inductive Load | 3A-250V AC | ||
| RATHED IMPULSE WITH- STAND VOLTAGE - Uimp | 1500 V | ||
| POSITIVE OPENING | NC positive opening | ||
| CONTACT BLOCKS | 1NC-1 NO changeover snap action / silver plated-self cleaning | ||
| PROTECTION CLASS | IP40 (IP00 terminals) in according to EN 60529 | ||
| OPTIONS | |||
| DOUBLE OVERHANG SHAFT | Available | ||
| POTENTIOMETER | According to customer request | ||
| ENCODER | - | ||
| CAM SHAPES | 5 different cam shapes | ||
| PINIONS | On request | ||